What are the differences in load-bearing capacity among stainless steel cable trays?

Sep 08, 2025 Leave a message

Stainless Steel Cable Trucking 1

By Structural Type: Load-Bearing Capacity: Ladder Type > Tray Type > Trough Type

Ladder type cable trays feature a grid-like steel frame, offering strong structural rigidity and evenly distributed loads. They offer the highest load-bearing capacity within the same specifications and are suitable for large-diameter cables and high-load applications (such as substation main lines). Tray type cable trays feature heat dissipation holes on the bottom and offer lower structural strength, making them suitable for medium- and low-load power cables. Trough type cable trays are fully enclosed box structures, focusing on protection. Their load-bearing capacity is relatively weaker, and they are mostly used for light-load applications such as weak-current cables.

2. By Material Grade: 316L ≈ 304 > 201

304 and 316L stainless steels have high chromium and nickel content, resulting in similar tensile strength (approximately 515 MPa) and yield strength (approximately 205 MPa), providing excellent load-bearing stability. 201 stainless steel has a low nickel content and a high manganese content. While its tensile strength is similar, it is prone to plastic deformation under long-term stress. Its actual load-bearing limit is 15%-20% lower than that of 304 at the same wall thickness, making it suitable only for light-load temporary wiring.

Stainless Steel Cable Ladder 3
Stainless Steel Cable Mesh 3

3. By Dimension: Thicker wall thickness and larger cross-section provide greater load-bearing capacity.

For the same structure and material, the larger the "width x height" ratio of the bridge and the thicker the wall thickness, the greater the load-bearing capacity. For example, a 150 x 100 mm (1.5 mm wall thickness) ladder bridge has a rated load of approximately 250 kg; a 200 x 100 mm (1.5 mm wall thickness) increases this to 320 kg. Increasing the wall thickness to 2.0 mm increases the rated load by another 20%-30% for the same cross-section.

4. By Installation Span: Smaller spans provide greater load margin.

The load-bearing capacity of the same bridge varies significantly with different spans. For example, a 100 x 50 mm ladder bridge has a rated load of approximately 180 kg at a 3-meter span. As the span increases to 6 meters, the load-bearing capacity drops by over 50%, to only approximately 80 kg. Therefore, for spans exceeding 6 meters, a reinforced bridge should be selected, or intermediate support points should be added to compensate for the load.

stainless steel cable tray 5

 

 