Product parameters
| Product Name: | Fire-Resistant Cable Trunking |
| Type: | cable trunking/cable duct/cable raceway/cable channel/wireway/cable trough/trough type cable tray/ventilated trough cable tray/fiber trough panduit/fireproof cable tray/different types of cable tray/cable tray management system |
| Material: | Fire-Resistant Steel |
| Surface Treatment: | Epoxy Spray Coating/Galvanized sheet |
Product Size
| Width: | 50-1200mm |
| Side Rail Height: | 25-300mm |
| Length: | 2000mm,3000-6000mm or Customization |
| Thickness: | 0.6-3mm |
Steel Thickness (Recommend)
| 1.0mm--Width: | 50~100mm |
| 1.2mm--Width: | 100~150mm |
| 1.5mm--Width: | 200~500mm |
| 2.0mm--Width: | 600~700mm |
| 2.5mm--Width: | 800~1000mm |
| As customer requirements | |
Other Characteristics
| Color: | As customer requirements |
| Certification: | CMA/ILAC-MRA/CNAS/CE |
| Application: | Wiring system,cable management,electromechanical system,construction industry and so on. |
| Non standard specifications are availabe according to customer's requirement. | |
Fire-Resistant Cable Trunking
High Temperature Resistance
Ceramic silicone rubber or mica layer is
used, which can withstand 950'℃ high
temperature and continuous burning for
more than 90 minutes.
Strong Fire Resistance
Oxygen index ≥45, reaching Class A
non-flammable standard.
Stable Electricity
Insulation resistance remains >100MΩ at high temperature to ensure continuous circuit smoothness during fire.
Long Life
The inorganic material structure makes the service life up to 30 years, and the maintenance-free design reduces the overall cost by 40%.
Materials for making fire-resistant cable trunkings

The materials of fire-resistant cable troughs must meet the characteristics of fire resistance, heat insulation, flame retardancy, and high mechanical strength. Common types include inorganic non-metallic materials, metal composite materials, and organic polymer flame retardant materials. Among them, inorganic non-metallic materials are made of inorganic refractory materials as the core, combined with reinforcing materials such as glass fiber. They are characterized by high temperature resistance, non-combustion, and strong heat insulation. They are suitable for high-level fire resistance demand scenarios, such as fully enclosed fire-resistant inorganic trough boxes, whose fire resistance limit can reach 1-3 hours.
Metal composite materials use metal as the base material, and improve fire resistance through coating or composite structure, combining mechanical strength and certain fire resistance. For example, steel fireproof trough boxes use galvanized steel plate shell plus inner layer of fireproof coating or fireproof board. The fire resistance limit is usually 30-60 minutes, which is suitable for medium and low-level fire resistance requirements; aluminum-magnesium alloy fireproof trough boxes are lightweight and take into account heat dissipation and flame retardancy, and are often used in weight-sensitive scenarios.


Organic polymer flame retardant materials use polymer resin as the base material and add flame retardants to achieve fireproof performance. The fire resistance level is relatively low, but the processability is good and the cost is low. Typical products such as flame retardant plastic trough boxes are suitable for non-fire load cables or ordinary building lighting lines, and the fire resistance limit is usually ≤30 minutes.
The performance of different materials varies significantly. Inorganic non-metallic materials have the highest fire resistance limit (60-180min) and high mechanical strength, and are suitable for scenes such as power tunnels; metal composite materials have a medium fire resistance limit (30-60min) and are mostly used in industrial plants; organic polymer flame retardant materials have the lowest fire resistance level and the lowest cost. When selecting, it is necessary to comprehensively evaluate the scene fire resistance level, cable type and installation environment, and give priority to certified products that meet standards such as GB 29415.

Fire protection performance of closed and semi-closed cable trunking
The structural design of the cable trough is a key factor affecting its fire resistance. Different structures have significant differences in heat conduction control, flame spread suppression and mechanical protection capabilities.
The fully enclosed structure adopts a completely closed shell with sealed joints to form an independent cable protection space. This structure can effectively reduce the heat exchange between the cable and the outside world. In a fire, the external flame needs to break through the double barrier of the outer refractory material and the closed shell to contact the internal cable. Test data show that the internal temperature rise of the fully enclosed inorganic trough box is 20%-30℃ lower than that of the semi-enclosed structure in the fire resistance test, and the fire resistance limit can reach 60-180 minutes. In addition, the fully enclosed space prevents the flame from directly spraying onto the cable surface, delaying the spread of the flame, and can also resist external force impact, block the intrusion of smoke and toxic gases, and is suitable for scenes with extremely high requirements for fire resistance integrity, such as fire distribution lines.
The top surface of the semi-enclosed structure can be opened or partially opened, and the ventilation is good, but it also leads to more active air convection, and the external heat in the fire is easily radiated or conducted directly to the cable. In the fire resistance test, the internal temperature rise of the semi-enclosed steel trough box is 15%-25℃ higher than that of the fully enclosed structure, and the fire resistance limit is usually 30-60 minutes. The gap at the top may also become a channel for flames to enter, increasing the risk of fire spread. However, the semi-enclosed structure is conducive to heat dissipation during normal operation of the cable, and the cost is 10%-20% lower than that of the fully enclosed structure. It is suitable for ordinary building lighting wiring and other scenes with low fire resistance requirements.
In addition to fully enclosed and semi-enclosed structures, other designs will also affect the fire resistance of the cable trough. For example, the installation of fire-resistant partitions in the trough box can separate different cables to prevent the spread of fire; the sealing process at the joints of the trough box directly affects the fire resistance integrity; the heat dissipation hole design of some trough boxes needs to strictly limit the opening rate, otherwise it will reduce the fire resistance limit.
In terms of matching structural design with standards, according to relevant specifications, fully enclosed structures must meet the dual indicators of integrity and thermal insulation, and are suitable for scenarios with a fire resistance limit of ≥60 minutes; semi-enclosed structures can only be assessed for integrity, and are suitable for scenarios with a fire resistance limit of ≤45 minutes; fully enclosed structures must be used in special scenarios, and the impact resistance must be verified through flame impact tests. When actually selecting a cable, it is necessary to combine the cable type, environmental risk level, and regulatory requirements to find a balance between "fire resistance requirements" and "functional requirements.
Hot Tags: Fire-Resistant Cable Trunking, China Fire-Resistant Cable Trunking manufacturers, suppliers, factory, cable support truck, cable support wagon, wire support wagon, wire support truck