Pre-Galvanized Cable Mesh

Pre-Galvanized Cable Mesh

Pre-galvanized cable mesh is a type of cable laying equipment that uses galvanized raw materials (such as steel wire) during the manufacturing process. Its surface is covered with a uniform zinc layer, providing good corrosion resistance and durability, and is suitable for mildly corrosive environments. Pre-galvanized cable mesh has a smooth and uniform appearance, is easy to install, and has low cost, making it an ideal choice for indoor locations such as office buildings and data centers. In addition, its excellent anti-rust performance ensures the long-term and stable operation of the cable system, making it an economical and practical cable laying solution.

Product Introduction

Product parameters

Product Name: Pre-Galvanized Cable Mesh
Type: Cable Mesh/Wire Mesh Cable Tray/Wire Cable Mesh/Mesh-Type Cable Tray/Wire Cable Tray/Wire Mesh Cable/Cable Protection Mesh/Cable Tidy Mesh/Mesh Cable/Wire Cable Mesh/Cable Wire Mesh/Mesh Cable Management/Wire Cable Tray
Material: Cold-Rolled Steel/Hot-Rolled Steel
Surface Treatment: Zinc Coating

Product Size

 
Width: 50-1200mm
Side Rail Height: 25-300mm
Length: 2000mm,3000-6000mm or Customization
Thickness: 0.6-3mm

Steel Thickness (Recommend)

 
1.0mm-Width: 50~100mm
1.2mm-Width: 100~150mm
1.5mm--Width: 200~500mm
2.0mm--Width: 600~700mm
2.5mm--Width: 800~1000mm
As customer requirements

Other Characteristics

 
Color: As customer requirements
Certification: CMA/ILAC-MRA/CNAS/CE
Application: Wiring system,cable management,electromechanical system,construction industry and so on.
Non standard specifications are availabe according to customer's requirement.

 

 

 

Advantages of pre-galvanized cable mesh

 

Pre-Galvanized Cable Mesh 2

Long-term anti-corrosion and durable

The pre-galvanized cable mesh adopts the pre-galvanizing process of the base material. The zinc layer evenly covers all cut surfaces, including the cutting edge. The salt spray test can last up to 3000 hours without rust. It can also be equipped with an epoxy spray outer layer to provide double protection, which is particularly suitable for highly corrosive environments such as chemical and marine environments to ensure the long-term and stable operation of the cable management system.

Lightweight and high-strength, safe and reliable

The open grid structure design reduces the weight of the product by 40%, and the single span (2m) load-bearing capacity is not less than 500kg. It has passed the IK10 protection level test and has excellent impact resistance. It can still maintain structural integrity in complex industrial environments to ensure cable safety.

Pre-Galvanized Cable Mesh 3
Pre-Galvanized Cable Mesh 4

Intelligent wiring, efficient heat dissipation

The mesh rate is as high as over 60%, which significantly improves the cable heat dissipation efficiency by 30% and effectively reduces the line operating temperature. The product supports integrated intelligent temperature measurement optical fiber, which can monitor the cable temperature status in real time, detect abnormal conditions in time, and provide hardware support for intelligent operation and maintenance.

Easy installation and flexible adaptation

The modular splicing design allows for quick assembly without professional tools, greatly improving construction efficiency. It provides a variety of installation solutions such as side mounting, hoisting, and wall mounting, which can be flexibly selected according to the actual situation on site to meet the installation needs of different scenarios.

Pre-Galvanized Cable Mesh 5

 

 

Post-maintenance of pre-galvanized cable mesh

 

Regular inspection and cleaning

It is recommended to inspect once a quarter in ordinary environments and once a month in highly corrosive environments (such as coastal areas and chemical plants), focusing on checking easily corrosive parts such as welding points and cut edges. Use a soft brush or low-pressure water gun when cleaning to avoid strong acid and alkali cleaning agents from damaging the zinc layer.

Local repair and connector maintenance

Small area zinc layer damage (<5cm²) can be repaired by spraying cold galvanizing paint after grinding, and structural damage requires replacement of the entire section. Check the tightness of fasteners every six months, apply conductive anti-corrosion grease to the contact points of different metals, and ensure that the grounding resistance is ≤4Ω.

Environmental adaptation and intelligent monitoring

Anti-condensation heating belts can be installed in high humidity environments, and protective coatings can be sprayed annually in chemically polluted areas. The intelligent monitoring system needs to calibrate sensors every year and establish corrosion rate files (normally <1μm/year).

Emergency treatment and file management

Large-area zinc layer shedding (>10%), grid deformation or grounding failure must be handled within 48 hours. It is recommended to establish a maintenance log to record inspections and repairs, and to be equipped with professional testing tools (such as coating thickness gauges).

 

 

 

 

 